Manual.ly Logo

Rutenbeck UM-Cat.8.1/Class I 10G Manwal

0.0 · 0 Mga Rating

Manual PDF · 2 Pahina

Tagalog

M: QW-35-FL
Pahina

/ 2

Loading...
106690203fd32a0f978c89e6369fbef186fa page 1
Cat.8.1/Class I Universalmodul
Cat.8.1/Class I Universal Module
Montageanleitung | Installation instructions
Installation
In order to prevent malfunctioning, only use patch cables that
have been tested according to ISO/IEC 61935-2 with connectors
that are conform with ISO/IEC 60603-7-81.
Preparing the cable
1 Remove the cable sheathing along a total length of
minimum 40 mm (see Fig. 1).
2 Shorten the braided shield to approx. 10 mm (A) and pull
it back over the cable sheathing.
3 Remove the shielding foil and untwist the four wire pairs
(B).
4 Shorten the two wire pairs at a connecting end (e. g.
orange/brown) by approx. 10 mm longer than the other
two and slightly chamfer the ends.
Cable installation
5 Untwist the wire pairs. Initially insert the longer wire pairs
(C) in the wire distributor that has the same colour and
follow with the shorter wire pairs.
6 Firmly insert the corresponding wire pairs into the
coloured wire fixations (E) by hand.
7 Use a cutting tool (F) to shorten the protruding ends of
the wires so that all of the wires are flush (G) with the
tension relief part.
8 Open the module cover on the back (H).
9 Insert the wire distributor into the module head (I) ensur-
ing that it is correctly positioned (with the groove facing
upwards).
10 Ensure that the dust protection cap (K) is open.
11 Swivel the module cover in and press it together using a
pair of parallel action pliers (L).
12 Manually remove the other tension relief (J) from the
plastic holder and insert it into the guide rail (M).
13 Also lock this tension relief into place using a pair of par-
allel action pliers (2x click) – see Fig. 6.
14 If necessary, place the equipotential bonding (N) onto
the contact tongue (O, 2.8 mm flat connector) as shown
in Fig. 7.
15 Should it interfere, break the plastic holder (P) that is no
longer required after completing the cable installation.
Dismantling
16 In order to remove the cable from the universal module,
work in reverse order.
17 To open the universal module, press the unlocking
springs on the tension relief together and pull it out of the
guide from above.
18 Unlock the module cover by applying pressure using a
pair of parallel action pliers and swivel it back (see Fig. 8).
19 Remove the wire distributor from the back of the module
head.
Installation
Verwenden Sie ausschließlich geprüfte Patchkabel gemäß
ISO/IEC 61935-2 mit Steckern gemäß ISO/IEC 60603-7-81
um Fehlfunktionen zu vermeiden!
Kabelvorbereitung
1 Entfernen Sie den Kabelmantel auf einer Länge von
mindestens 40 mm (siehe Abb. 1).
2 Kürzen Sie den Geflechtschirm auf ca. 10 mm (A) und
ziehen diesen nach hinten über den Kabelmantel.
3 Entfernen Sie die Schirmfolie und entdrillen Sie die vier
Adernpaare (B).
4 Kürzen Sie zwei Adernpaare einer Anschlussseite (z. B.
orange/braun) um ca. 10 mm mehr als die beiden anderen
und schrägen Sie alle Enden leicht ab.
Kabelmontage
5 Entdrillen Sie die Adernpaare. Führen Sie zuerst die
längeren Adernpaare (C) in die farblich zugehörigen
Kammern des Adernverteilers ein und lassen dann die
kürzeren Adernpaare folgen.
6 Ziehen Sie die jeweiligen Adernpaare in die farbig mar-
kierten Adernfixierungen (E) mit der Hand fest hinein.
7 Kürzen Sie jetzt mit einem Schneidewerkzeug (F) die
überstehenden Aderenden, sodass alle Adern bündig
(G) mit dem Zugentlastungsteil abschließen.
8 Öffnen Sie den rückseitigen Moduldeckel (H).
9 Führen Sie den Adernverteiler lagerichtig – mit der Nut
nach oben – von hinten in den Modulkopf (I) ein.
10 Stellen Sie sicher, dass die Staubschutzkappe (K)
geöffnet ist.
11 Schwenken Sie den Moduldeckel ein und drücken Sie
diesen mit einer Parallelhubzange (L) zusammen.
12 Nehmen Sie die andere Zugenlastung (J) mit der Hand
aus der Kunststoffhalterung heraus und führen Sie diese
in die Führungsschiene (M) ein.
13 Verrasten Sie auch diese Zugentlastung mit einer Paral-
lelhubzange fest (2x Klick) – siehe Abb. 6.
14 Bei Bedarf stecken Sie den Potentialausgleich (N) – wie
in Abb. 7 dargestellt – auf die Kontaktzunge (O, Flach-
steckverbinder 2,8 mm).
15 Wenn störend, brechen Sie zum Abschluss der Kabel-
montage die nicht mehr benötigte, weiße Kunststoffhal-
terung (P) ab.
Demontage
16 Gehen Sie zur Entnahme des Kabels aus dem Universal-
modul generell in umgekehrter Reihenfolge vor.
17 Drücken Sie zum Öffnen des Universalmoduls die seit -
lichen Entriegelungsfedern der Zugentlastung zusammen
und nehmen diese nach oben aus der Führung heraus.
18 Entrasten Sie den Moduldeckel mittels Druck einer Paral-
lelhubzange und schwenken diesen nach hinten auf –
siehe Abb. 8.
19 Entnehmen Sie den Adernverteiler von hinten aus dem
Modulkopf.
Technical Support
+ 4 9 2 3 5 5 82-111
Commercial Support
+49 2355 82-137
4
J
H
I
5
L K
6
7
8
N O
P
1
A B
10 6
min. 40 mm
3
FG
2
D
C
E
M

Makipag-chat sa iyong Rutenbeck UM-Cat.8.1/Class I 10G manual gamit ang AI

Makakuha ng agarang sagot mula sa AI batay sa iyong Rutenbeck UM-Cat.8.1/Class I 10G manual

Magtanong ng kahit ano tungkol sa Rutenbeck UM-Cat.8.1/Class I 10G. Ang mga sagot ay mula sa manual na ito, kasama ang mga pahinang pinagbatayan.

Magtanong Tanong

0/1000

Inirerekomenda mo ba ang UM-Cat.8.1/Class I 10G?

Oo Hindi

Madalas Na Tanong

A

Ang Rutenbeck UM-Cat.8.1/Class I module ay sumusuporta sa data rates hanggang sa 40 Gbps sa channel lengths hanggang sa 30 meters, na ginagawang angkop ito para sa high-speed backbone connections at data center interconnects.

Nakakatulong ba ang sagot na ito?

A

Oo, ito ay dinisenyo partikular para sa pagpasok sa standard na butas ng module keystone, na nagbibigay-daan sa madaling integrasyon sa mga wall plates at patch panels na ginagamit sa commercial at industrial settings.

Nakakatulong ba ang sagot na ito?

A

Totoo. Ang module ay nasisertipiko para sa PoE+ suitability ayon sa IEEE 802.2at, na kayang hawakan ang 500 mA operating current sa 50 degrees Celsius ambient temperature.

Nakakatulong ba ang sagot na ito?

A

Kailangan mo ng cutting tool para sa pagtitihi ng wires, parallel action pliers para sa pagseguro ng cover at tension relief, at standard crimping tools kung naghahanda ka ng sarili mong patch cables ayon sa mga pamantayang ISO.

Nakakatulong ba ang sagot na ito?

A

Habang pisikal na posible, ang paggamit ng unshielded cables ay nagtatapon ng layunin ng shielded design at maaaring magresulta sa signal degradation dahil sa increased susceptibility sa crosstalk at interference.

Nakakatulong ba ang sagot na ito?

A

Ang module ay rated para sa minimum na 750 mating cycles, na nagtitiyak ng long-term durability para sa madalas na plugged at unplugged connections sa active network environments.

Nakakatulong ba ang sagot na ito?

M: QW-35-FL

Mga Pakinabang at Kahinaan

Mga Kalamangan

  • Sumusuporta sa mga pamantayan ng Cat.8.1 Class I para sa 10G at 40G speeds
  • Superior shielding ay nagprotekta laban sa electromagnetic interference
  • Kompatible sa parehong TIA/EIA-568-A at B wiring schemes
  • Halogen-free material ay nagpapalakas ng fire safety at environmental compliance
  • Robust tension relief system ay pigilan ang cable strain at disconnection
VS

Mga Kahinaan

  • Nangangailangan ng specific parallel action pliers para sa tamang pag-install
  • Mahigpit na pagsunod sa mga hakbang ng paghahanda ng kable ay kinakailangan para sa function
  • Mas mataas na cost kumpara sa unshielded Cat.6A alternatives
  • Limitadong ambient temperature range kumpara sa ilang industrial grades
  • Kumplikadong dismantling procedure ay nangangailangan ng reverse order ng assembly
M: QW-35-FL

Produkto Spesipikasyon

Uri

Keystone Module (1x RJ-45, Cat8.1 Class I, via RJ-45 jack)

Mga Katangian

buong nakapagpakidnap

M: QW-35-FL

Produkto Paglalarawan

Rutenbeck UM-Cat.8.1/Class I 10G Universal Module: Ang Solusyon na May Kalasok para sa Mabilisang Network

Ang Rutenbeck UM-Cat.8.1/Class I 10G Universal Module ay kumakatawan sa isang malaking pag-unlad sa estrukturadong imprastraktura ng kable, na dinisenyo partikular para sa mga kapaligiran na nangangailangan ng pinakamataas na integridad ng data at bilis. Ang module na may kalasok na ito ay inihanda upang suportahan ang mga pamantayan ng Cat.8.1, na nagtitiyak ng maaasahang pagganap hanggang sa 40 Gbps sa maikling distansya habang pinapanatiling likod-kompatibilidad sa mas mababang kategorya. Ang matibay nitong konstruksyon ay nagsisilidang perpektong pagpipilian para sa mga modernong sentro ng data at network ng antas na negosyo kung saan ang interferensya ng signal ay dapat kontroladong husto.

Dinisenyo para sa walang sagabal na integrasyon sa mga butas ng module keystone, ang komponenteng universal na ito ay nag-aalok ng napakagandang fleksibilidad sa panahon ng pag-install. Ang yunit ay may komprehensibong sistema ng relief ng tensyon na nagse-secure sa kable laban sa mekanikal na stress, na isang kritikal na salik sa pagpapanatili ng konsistenteng katangian ng transmisyon sa loob ng oras. Ang kalasok ay nagbibigay ng superyong proteksyon laban sa alien crosstalk at eksternal na elektromagnetikong interferensya, na karaniwang hamon sa siksik na tray ng kable. Sa pagsunod sa mga pamantayang ISO/IEC 61935-2 para sa patch cables at konektor, ang module ay tinitiyak na ang buong link ay tumutugma sa mahigpit na mga requirement ng sertipikasyon nang walang kompromiso.

Ang pag-install ay simpleng sundin kapag sumusunod sa mga tiyak na gabay na ibinigay ng tagagawa. Ang proseso ay nangangailangan ng maingat na paghahanda ng balat ng kable, tamang paghawak ng braided shield, at mapagmasid na pagkakasunod-sunod ng apat na wire pairs sa loob ng internal distributor. Ang module ay gumagamit ng sistemang fixation ng wire na may kulay na nagpapaliit ng terminasyon para sa parehong TIA/EIA-568-A at TIA/EIA-568-B na mga scheme ng wiring. Kapag tama na ang mga wire na nakaupo at tinahi nang patago, ang takip ay siguraduhin gamit ang parallel action pliers, na nakakulong ang assembly nang mahigpit sa lugar. Isang natatanging katangian ay ang potensyal para sa equipotential bonding, na nagpapalakas ng kaligtasan at integridad ng grounding sa kumplikadong kapaligiran ng elektrikal.

Bukod sa pisikal na durability, ang module ay may impresibong teknikal na specs na angkop sa mga aplikasyon ng PoE+. Suportado nito ang rated voltage na 72 V DC at kaya maghanap ng operating currents hanggang sa 500 mA sa mataas na temperatura. Na may dielectric strength na 1,000 V sa pagitan ng mga contacts at minimum insulation resistance na 500 MΩ, ang device ay tinitiyak ang long-term reliability kahit sa ilalim ng demanding electrical loads. Ang halogen-free construction ay mas nagpapahiwatig ng komitment sa environmental safety at fire resistance. Kung gagamitin ito para sa bagong installations o pag-upgrade ng umiiral na imprastraktura, ang Rutenbeck UM-Cat.8.1 ay nananatiling premium na solusyon para sa mga propesyonal na network architect na naghahanap ng walang kompromiso na performance at madaling gamitin.

Mahahalagang Gabay sa Pag-install

Siguraduhing lahat ng patch cables na ginamit ay nasubok ayon sa ISO/IEC 61935-2 upang maiwasan ang malfunctioning. Palaging i-verify na bukas ang dust protection cap bago pumasok ang wire distributor. Gamitin lamang ang parallel action pliers para sa pagseguro ng module cover at tension relief components upang maiwasan ang pinsala sa housing.

M: QW-35-FL

© Copyright 2026 Manual.ly